Once the system is placed in automatic mode, linkage and swing movement may occur. Ensure that all personnel are clear of the machine before you place the system in automatic mode. Personal injury could occur. |
If Grade with Assist is installed and Software Enabled Attachment (SEA) is enabled, then a button is added to the Cat@ Grade Control screens. This button is used to select manual or auto.
![]() | |
Illustration 1 | g03874655 |
Multi-Information Area with Button to Select Auto Mode |
![]() | |
Illustration 2 | g03874678 |
Multi-Information Area with Auto Mode Indicated |
When in auto mode, all auto functions are enabled.
Note: In auto mode e-ceiling and e-floor are active, and the linkage is stopped when the limit height or depth has been reached.
![]() | |
Illustration 3 | g03874649 |
Multi-Information Area with Button to Select Manual Mode |
![]() | |
Illustration 4 | g03874670 |
Multi-Information Area Manual Mode Indicated |
When in manual mode no auto functions are enabled except for e-ceiling and e-floor.
Note: In manual mode e-ceiling and e-floor are active, and an alarm is indicated when the linkage limit height or depth has been reached.
![]() | |
Illustration 5 | g03874677 |
Auto Cancel Mode Indicated |
When in auto cancel mode, auto is prohibited due to system condition.
Monitor With Installed Cat Grade With Assist With Tilt (If Equipped)
This is an additional available function to the Cat Grade With Assist. This function uses the tilt bucket and the tilt bucket angle sensor to allow for greater control of the bucket. The bucket focus selections and tilt are available for display on the monitor.
![]() | |
Illustration 6 | g06108945 |
Bucket icon states (A) Center focus, left tilt (B) Center focus, flat tilt (C) Center focus, right tilt (D) Right focus, left tilt (E) Right focus, flat tilt (F) Right focus, right tilt (G) Left focus, left tilt (H) Left focus, flat tilt (J) Left focus, right tilt |
Illustration 6 shows the various angle states of the direction of the bucket slope and the bucket focus states for the icon. The square on the bucket indicates the position of the bucket focus.
Note: The default bucket focus position is bucket center.
![]() | |
Illustration 7 | g06108996 |
Bucket focus state selection monitor |