Improved Jacket Water Circuit Breaker for Certain Electric Power Generators and Work Tools{1383, 1417, 1420} Caterpillar


`
Improved Jacket Water Circuit Breaker for Certain Electric Power Generators and Work Tools{1383, 1417, 1420} [REHS5199]
ELECTRICAL AND STARTING SYSTEM
CIRCUIT BREAKER GP
Improved Jacket Water Circuit Breaker for Certain Electric Power Generators and Work Tools{1383, 1417, 1420}
1.1. Introduction
2.1. Important Safety Information
3.1. Required Parts
4.1. Replacement Procedure for the Circuit Breaker
Electric Power Generation:
C2.2 GEN SET (S/N: GBE1-UP)
C4.4 GEN SET (S/N: N4R1-UP; N4X1-UP)
Work Tool:
S365 (S/N: CLE1-UP)
S365 SHEAR (S/N: CLE1-UP)

Introduction

This Special Instruction will guide you through the procedure to replace the circuit breaker for the jacket water heater. This new circuit breaker will improve the reliability of the jacket water heater.

Important Safety Information

Do not perform any procedure in this Special Instruction until you have read this Special Instruction and you understand this information. Use only proper tools and observe all precautions that pertain to the use of those tools. Failure to follow these procedures can result in personal injury. The following procedures should also be observed.

Work safely. Most accidents that involve product operation, maintenance, and repair are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs.

A person must be alert to potential hazards. This person should also have the necessary training, skills, and tools in order to perform these functions properly.

Safety precautions and warnings are provided in this instruction and on the product. If these hazard warnings are not heeded, bodily injury or death could occur to you or to other persons. AVSpare cannot anticipate every possible circumstance that might involve a potential hazard.

Therefore, the warnings in this publication and the warnings that are on the product are not all inclusive. Ensure that any tool, procedure, work method, or operating technique you use that is not recommended by AVSpare is safe.

Ensure that the product will not be damaged or the product will not be made unsafe by the operation, lubrication, maintenance, or repair procedures used.

Required Parts

Table 1
Required Parts    
Part Number     Description     Quantity    
286-4744     Circuit Breaker     1    

Replacement Procedure for the Circuit Breaker

------ WARNING! ------

When servicing or repairing electric power generation equipment:

  • Make sure the unit is either locked out or tagged DO NOT OPERATE.

  • Remove all fuses.

  • Make sure the generator engine is stopped.

  • Make sure all batteries are disconnected.

  • Make sure all capacitors are discharged.

  • Make sure residual voltage in the rotor, stator and the generator is discharged.

Failure to do so could result in personal injury or death.

----------------------

Note: Isolate the generator before beginning any type of work. Ensure proper Lock Out-Tag Out procedures are followed at all times while work is being performed on the machine. Lock out generator before beginning any type of work.

  1. Open the generator set breaker and activate the emergency stop.

  1. Disconnect the battery cables and the auxiliary power supply for the battery charger and heaters.

  1. Locate the MCB12 circuit breaker on the panel chassis.



    Illustration 1g02150396

  1. Disconnect wire 132- and wire 134- from the terminals (1) .

  1. Remove MCB12 from the DIN rail by placing a small flat blade screwdriver into the spring loaded latch (2) .

  1. Install the 286-4744 Circuit Breaker into the opening and ensure that the circuit breaker is locked into the DIN rail.

  1. Reinstall wire 132- and wire 134- on the circuit breaker terminals (1) .

  1. Reconnect any power supplies or auxiliary supplies that were disconnected in Step 2.

  1. Verify that the jacket water is fully functional and operating correctly.

Information System:

MP15, MP20, MP30 and MP40 Multi-Processors Cutting Edges - Inspect/Replace
MP15, MP20, MP30 and MP40 Multi-Processors Rotator Gear - Lubricate
MP15, MP20, MP30 and MP40 Multi-Processors Bushings - Lubricate
C9.3 Engines for Caterpillar Built Machines Engine Oil Filter Base - Remove and Install
349E Excavator Hydraulic System Return Hydraulic System
C6.6 Industrial Engine Flywheel Housing - Remove and Install - Standard Housing
C6.6 Industrial Engine Crankshaft Rear Seal - Install
C6.6 Industrial Engine Crankshaft Rear Seal - Remove
C6.6 Industrial Engine Flywheel - Install
C6.6 Industrial Engine Flywheel - Remove
C6.6 Industrial Engine Water Temperature Regulator - Remove and Install
C6.6 Industrial Engine Water Pump - Install
336E Excavator and 336E MHPU Mobile Hydraulic Power Unit Machine Systems Stick - Remove and Install
C9.3 Engines for Caterpillar Built Machines Inlet Manifold - Remove and Install
2010/05/20 An Improved Hydraulic Tank is Available for Certain Excavators {5056}
2010/05/06 Improved Remanufactured Injectors Are Now Used on Some 3408E and 3412E Machine Engines {1251, 1254, 1290, 1713}
C13 Tier 4 Final Engines Exhaust Cooler (NRS) - Clean
MP15, MP20, MP30 and MP40 Multi-Processors Rotator Head Bolts - Check
MP15, MP20, MP30 and MP40 Multi-Processors Rotator Head Bolts - Check
MP15, MP20, MP30 and MP40 Multi-Processors Rotator Head Bolts - Check
C15 and C18 Tier 4 Final Engines Exhaust Cooler (NRS) - Test
MP15, MP20, MP30 and MP40 Multi-Processors Rotator Head Bolts - Inspect
MP15, MP20, MP30 and MP40 Multi-Processors Rotator Head Bolts - Inspect
MP15, MP20, MP30 and MP40 Multi-Processors Wear Plates - Inspect/Replace