Illustration 1 | g00838428 |
In order to reach the "Configuration" menu, go to the "Service Option PW" menu. See Systems Operation, "Service Options PW Menu" for more information. After you have reached the menu, press the down key (6) in order to highlight "CONFIGURATION". Press the OK key (8).
Illustration 2 | g00838426 |
Press the left key (5) or press the right key (2) in order to scroll through the configuration screens. The items that are available for configuring are listed in table 1.
Note: Modifications to the configuration must be done via Cat ET.
All of the items listed may not apply to all machine models depending on attachments or machine configurations.
Configuration Menu     | |
Description     | Possible Values     |
"Travel Alarm"     | Installed / Not Installed     |
"Boom Angle Switch"     | Installed / Not Installed     |
"Refueling Pump"     | Installed / Not Installed     |
"Quick Coupler"     | Installed / Not Installed     |
"Implement Generator"     | Installed / Not Installed     |
"Aux Tool Control Valve"     | Installed / Not Installed     |
"Hammer"     | Installed / Not Installed     |
Travel Pedal Lock     | Installed / Not Installed     |
Hydraulic Modulation     | Installed / Not Installed     |
Meduim Pressure Attachment     | Installed / Not Installed     |
Hydraulic Cab Riser (HCR)     | Installed / Not Installed     |
Joystick Steering     | Installed / Not Installed     |
"AESC Delay"     | sec (seconds)     |
Max Machine Speed     | km/h     |
Offset Boom     | Installed / Not Installed     |
When you reach the item, press the OK key (8). Press the left key (5) or press the right key (2) in order to select the configuration.
Note: When the parameter is not available, the bottom row shows "- - - - ".