Numerous VIMS service operations can be initiated by the operator or a service technician. A unique service program code (SPC) is assigned to each of the service operations. The service program codes are entered through the VIMS keypad module. Entering the service program code starts the corresponding service operation. The service operations are listed in Table 1.
VIMS Service Operations     | |||
---|---|---|---|
Service Operation     | Service Program Code     |
Service Program Code     |
Page Number     |
"Attachment Code - configure"     | "ATTACH"     | 288224     | ??     |
"Data Logger - Reset "     | DLRES     | (35737)     | 11     |
"Data Logger - Start/Stop"     | DLOG     | (3564)     | 12     |
"Display Backlighting - Set"     | BLT     | (258)     | 12     |
"Display Contrast - Set"     | CON     | (266)     | 12     |
"Display Language - Set"     | LA     | (52)     | 13     |
"Display Units - Set"     | UN     | (86)     | 13     |
"Event Acknowledged - Show"     | EACK     | (3225)     | 15     |
"Event List - Show"     | ELIST     | (35478)     | 15     |
"Event Statistics - Show"     | ESTAT     | (37828)     | 16     |
"Lubrication Cycle Time - Set"     | LUBSET     | (582738)     | 16     |
"Lubrication Manual - Start"     | LUBMAN     | (582626)     | 17     |
"Machine Status - Show"     | MSTAT     | (67828)     | 18     |
"Resettable Totals - Reset"     | RESET     | (73738)     | 19     |
" Resettable Totals - Show"     | TOT     | (868)     | 19     |
"Service Lamp - Reset"     | SVCLIT     | (782548)     | 19     |
"Service Lamp - Set"     | SVCSET (1)     | (782738)     | 19     |
"Snapshot Trigger - Configure"     | ERSET (1)     | (37738)     | 22     |
System Self Test     | TEST     | (8378)     | 24     |
"VIMS Snapshot - Start"     | EREC     | (3732)     | 26     |
( 1 ) | The service tool is required to be connected and communicating with the machine before this SPC is active. |
Each service program code is a unique number of one to ten digits that abbreviates this operation. The service program codes have a letter equivalent that describes the service operation. This letter equivalent makes remembering the service program code for each operation easier. The English letter equivalent for each service program code is shown in the parentheses. The same service program codes are used regardless of the onboard language.
After you enter the service program code on the keypad, the request will begin after you press the "OK" key. You must activate this command within five seconds of entering the last SPC character. The maximum delay that is allowed between the entry of the SPC characters is five seconds .