Operation

The service codes for the hydraulic hammer are in the following list: 86, 87, 88 and 8A. The service codes are used in order to adjust the main hydraulic pump flow. The flow is adjusted in order to correspond with the flow that is required for a hydraulic hammer. Three different parameters can be set and stored into the memory of the controller. The parameters are in the following list:

  • Number of Main Hydraulic Pumps

  • Circuit Pressure of the Hydraulic Hammer

  • Pump Flow that is Required

Use the following procedure in order to enter the hammer mode.

  1. Depress user mode button (5) .

  1. Select the "U2" mode.

When the hammer circuit attachment is activated, the controller regulates the power shift pressure. The power shift pressure is regulated in order to regulate the main pump(s). This ensures that the flow requirements and/or the pressure requirements for the hammer or for other attachments are not exceeded.

The parameters that are set in the user mode will only affect the operation of the main pump, when the hammer pedal is activated individually. When the position of the engine speed dial is changed, the controller automatically changes the power shift pressure. This ensures that the flow rate of the pump(s) are changed in order to compensate for the engine speed changes.

Modes

Mode "U1" is the tamping mode. This mode is set at the factory. The tamping mode can not be adjusted.

Mode "U2" is the hammer mode. This mode can be selected and adjusted by the operator and the service technician.

Mode "U3" is the user mode. This mode allows the user to adjust various parameters. Access to the service mode is not necessary.

Setting the Parameters of the Hammer Mode

Hammer Mode

The hammer mode is used for attachments. Excavating requires more flow of oil than the operation of an attachment. When an attachment is operated, the power shift pressure is kept constant. The constant pressure is preset.

The parameters that are set in the user mode will only affect the operation of the main pump, when the hammer pedal is activated individually. When the position of the engine speed dial is changed, the controller automatically changes the power shift pressure. This ensures that the flow rate of the pump(s) are changed in order to compensate for the engine speed changes.

The flow rates for one pump are in the following list:

  • When the pressure is 13.6 MPa (1972.5 psi), the flow is a maximum of 313 L/min (83 US gpm).

  • When the pressure is less than 13.6 MPa (1972.5 psi), the flow is a minimum of 142 L/min (38 US gpm).

Note: The flow rates are measured at the rated speed of the engine.

Hammer Mode Preset

When a hydraulic hammer is used, select the "U2" mode. If the other work modes are selected, the maximum pump flow will be sent to the hammer. Maximum flow will damage the hammer. In order to avoid damage, a security code is available. Changing the setting of the software will ensure that the correct flow of oil is sent to the hammer when the hammer pedal is activated. This is accomplished regardless of the work mode that is selected. The following procedure is used in order to set the preset for the hammer mode.

Note: The default value of the preset is "OFF".

  1. Access the service mode.

    1. Depress travel alarm cancel switch (3). Hold switch (5) and depress fine control mode switch (4) and user mode switch (5) .

    1. Hold the three switches for a minimum of 2 seconds. The character display will indicate "0". The character on the left side of the display will flash.

  1. Enter service code 080251.

  1. When the indicators "10" or "80" appear in the monitor, enter the new service code "89" on the character display.

  1. Depress fine control mode switch (5) in order to shift the blinking character. Position the blinking character to the left position.

  1. Depress boom priority mode switch (1) in order to display "89oN" or "89oF".

    When the character display indicates "89oN", hammer mode is activated when the hammer pedal is pushed under any work mode. This allows the preset pump flow to be sent to the hammer.

    When the character display indicates "89oF", hammer mode is not activated when the hammer pedal is pushed. This allows the maximum pump flow to be sent to the hammer.

  1. Enter "89oN" on the character display.

  1. Set the new value for the AEC.

    1. Depress travel alarm cancel switch (3) in order to set the new values.

      When the new value is set, the position of the blinking character does not change. The service code flashes.

Procedure to Set the Parameters for the Hammer Mode

  1. Verify the specification of the hammer.

    When the hammer requires a maximum pump flow of 250 L/min (66 US gpm), use one pump to supply the flow.

  1. Set the number of pumps that are used. Refer to "Setting the Number of Pumps".

  1. Set the pressure for the hammer mode. Refer to "Setting the Circuit Pressure".

  1. Set the pump flow for the hammer mode. Refer to "Setting the Pump Flow".

    If the desired speed of the hammer is not achieved, the flow rate can be adjusted. This is due to the imbalance of the associated components. When you increase the flow rate, the speed of the hammer decreases. If the speed of the hammer does not change, service the hydraulic system.

Setting the Number of Pumps

Service code 86 changes the number of pumps that is used in the calculation for the power shift between the pumps.

  1. Enter service code 86.

    The number of pumps that are used by the hammer mode is displayed.

    • "861" indicates that 1 pump is selected.

    • "861" indicates that 2 pumps are selected.

  1. Depress fine control mode switch (4) in order to shift the blinking character. Position the blinking character to the position on the right.

  1. Depress boom priority mode switch (1) in order to change the number of pumps from 1 to 2.

  1. Depress swing priority mode switch (2) in order to change the number of pumps from 2 to 1.

  1. Set the new value for the AEC.

    1. Depress travel alarm cancel switch (3) in order to set the new values.

      When the new value is set, the position of the blinking character does not change. The service code flashes.

Setting the Circuit Pressure

Service code 87 adjusts the calculation of the pressure of the circuit that is used for the power shift between the pumps.

Note: The pressure that is set in the following procedure must match the low pressure setting for the line relief valve that is in the circuit.

  1. Enter service code 87.

    The set pressure in the hammer mode is displayed in a unit of MPa.

  1. Depress fine control mode switch (4) in order to shift the blinking character. Position the blinking character to the position on the right.

  1. Depress boom priority mode switch (1) in order to INCREASE the pressure by 1 MPa (145 psi).

    The pressure range is between 10 MPa (1450 psi) and 35 MPa (5076 psi).

  1. Depress swing priority mode switch (2) in order to DECREASE the pressure by 1 MPa (145 psi).

    The pressure range is between 10 MPa (1450 psi) and 35 MPa (5076 psi).

  1. Set the new value for the AEC.

    1. Depress travel alarm cancel switch (3) in order to set the new values.

      When the new value is set, the position of the blinking character does not change. The service code flashes.

Setting the Pump Flow

Service code 88 adjusts the target of the flow rate that is used by the calculation for the power shift between the pumps.

  1. Enter service code 88.

    The set pressure in the hammer mode is displayed in liter per minute.

  1. Depress fine control mode switch (4) in order to shift the blinking character. Position the blinking character to the position on the right.

  1. Depress boom priority mode switch (1) in order to INCREASE the flow by 1 L/min (0.26 US gpm).

    The range of the flow rate is between 30 L/min (7.9 US gpm) and 250 L/min (66 US gpm).

  1. Depress swing priority mode switch (2) in order to DECREASE the flow by 1 L/min (0.26 US gpm).

    The range of the flow rate is between 30 L/min (7.9 US gpm) and 250 L/min (66 US gpm).

  1. Set the new value for the AEC.

    1. Depress travel alarm cancel switch (3) in order to set the new values.

      When the new value is set, the position of the blinking character does not change. The service code flashes.

Setting the Power Offset

Service code 8A adjusts the value of the power offset in order to reduce the main pump output. This is accomplished when the third pedal is operated in order to activate an attachment pump.

  1. Enter service code 8A.

    The set power offset in the hammer mode is displayed in percent.

  1. Depress fine control mode switch (4) in order to shift the blinking character. Position the blinking character to the two positions on the right.

  1. Depress boom priority mode switch (1) in order to INCREASE the power offset by 1 percent.

    The power offset can be between 0 and 30 percent.

  1. Depress swing priority mode switch (2) in order to DECREASE the power offset by 1 percent.

    The power offset can be between 0 and 30 percent.

  1. Set the new value for the AEC.

    1. Depress travel alarm cancel switch (3) in order to set the new values.

      When the new value is set, the position of the blinking character does not change. The service code flashes.

Information System:

345B, 345B Series II and W345B Series II Excavators Engine and Pump Control Parameter - Adjust
345B, 345B Series II and W345B Series II Excavators Engine and Pump Control Troubleshooting Undiagnosed Problems
345B, 345B Series II and W345B Series II Excavators Engine and Pump Control Real Time Error Codes
305 CR Mini Hydraulic Excavator Cooling System Coolant (ELC) - Change
Horizontal Pin Lock Series PW Quick Coupler Rated Load
345B Series II Excavator Hydraulic System Main Control Valve
305.5 Mini Hydraulic Excavator Bucket Tips - Inspect/Replace
432D and 442D Backhoe Loaders Equipment Lowering with Engine Stopped
M316C, M318C and M322C Excavators and M318C and M322C Material Handlers Lubricant Viscosities
305 CR Mini Hydraulic Excavator Boom and Stick Linkage - Lubricate
416C, 426C, 428C, 436C and 438C Backhoe Loaders Quick Coupler Operation (Backhoe) - Pin Grabber Quick Coupler (If Equipped)
420D and 430D Backhoe Loaders Quick Coupler Operation (Loader)
345B, 345B Series II and W345B Series II Excavators Engine and Pump Control Engine Speed Dial Setting - Check
345B, 345B Series II and W345B Series II Excavators Engine and Pump Control Digital Output On/Off - Test
345B, 345B Series II and W345B Series II Excavators Engine and Pump Control Electronic Governor - Calibrate
345B, 345B Series II and W345B Series II Excavators Engine and Pump Control Proportional Reducing Valve Sweep - Test
345B, 345B Series II and W345B Series II Excavators Engine and Pump Control Proportional Reducing Valve - Calibrate
345B, 345B Series II and W345B Series II Excavators Engine and Pump Control Speed Sensor - Replace
345B, 345B Series II and W345B Series II Excavators Engine and Pump Control Controller Input and Output Values
325C Excavator Machine System Specifications Boom - 5550 mm (218.5 inch)
3500B, 776D, 777D, 784C, 785C, 789C, 793C and and 793D Off-Highway Truck/Tractors Refrigerant Compressor
305 CR Mini Hydraulic Excavator Engine Air Filter Primary Element - Clean/Replace
325C Excavator Machine System Specifications Boom - 6150 mm (242.1 inch)
305 CR Mini Hydraulic Excavator Engine Oil Level - Check