Calibration of the joystick thumbwheels can be performed by using two methods, calibration with the monitor and calibration with AVSpare Electronic Technician.
Calibration with Monitor
Note: Use the keys in the following illustration in order to calibrate the joystick slide control.
![]() | |
Illustration 1 | g01197980 |
(1) Up key (2) Right key (3) Home key (4) Main menu (5) Left key (6) Down key (7) Cancel key (8) OK key |
Recalibration must be performed if any of the following components are replaced:
- The joystick slide control
- The tool controller
- The software
Place the backup switch in the AUTO position.
- In order to access the "CALIBRATION" menu, enter the "SERVICE" mode on the monitor.
- Enter the service mode. Refer to Testing and Adjusting, "Service Mode - Enter" for the Tool Control.
- From the "SERVICE" menu, use the up key (1) or the down key (6) in order to move the highlighted line.
![]() | |
Illustration 2 | g01199794 |
Typical example of the "SERVICE" menu for the monitor |
- When the "CALIBRATIONS" menu option is highlighted, press the OK key (8). Refer to Illustration 2.
- After the OK key is pressed, the "CALIBRATIONS" screen will appear. From the "CALIBRATIONS" menu, highlight "LEVER / PEDAL / ATCH".
![]() | |
Illustration 3 | g01199796 |
- When the "LEVER / PEDAL / ATCH" option is highlighted, press the OK key (8). Refer to Illustration 3.
- After the OK key is pressed, the "LEVER / PEDAL / ATCH" screen should appear. Use the down key in order to highlight "MOD L THUMBWHEEL". Press the OK key (8) .
Note: Illustration 4 shows that both the left thumb wheel and the right thumb wheel are highlighted. Only one of the options will be highlighted at a time.
![]() | |
Illustration 4 | g01199800 |
- After the OK key is pressed, the monitor will begin to communicate to the ECM. When the ECM is ready, the next screen will automatically appear.
![]() | |
Illustration 5 | g01199803 |
- Press the OK key (8) in order to start the process of calibration. After the OK key is pressed, all inputs will be disabled.
![]() | |
Illustration 6 | g01199818 |
- Ensure that the thumb wheel is in the neutral position. Press OK key (8) .
![]() | |
Illustration 7 | g01199822 |
- Move the thumb wheel to the FORWARD position. move the thumb wheel to the BACKWARD position.
![]() | |
Illustration 8 | g01199823 |
- Allow the inputs to return to the NEUTRAL position. Press the OK key (8) .
- Press the OK key (8). Pressing the OK key enables the machines inputs.
![]() | |
Illustration 9 | g01199825 |
- The process of calibrating is completed. Press the cancel key (7) in order to exit the upper level screen.
![]() | |
Illustration 10 | g01199827 |
- It is possible for an error to occur when you are calibrating. If an error occurs during the process of calibrating, restart the process of calibrating.
![]() | |
Illustration 11 | g01199830 |
- Repeat Steps 7 through Step 15 for the right thumb wheel.
Calibration with AVSpare Electronic Technician
- The calibrations initial start-up displays the following: "Left Joystick Thumbwheel Calibration", "Right Joystick Thumbwheel Calibration", "Left Attachment Pedal Calibration" and "Right Attachment Pedal Calibration". Perform one calibration at a time. Follow the instructions in order to perform the calibration.
![]() | |
Illustration 12 | g01203270 |
- As the calibration is being performed, the active step will be displayed in bold text.
![]() | |
Illustration 13 | g01203273 |
- After the completion of a step, a check will appear in the completed box. Press the "NEXT" button in order to continue to the next step of calibration.
![]() | |
Illustration 14 | g01203281 |
- When the calibration is completed, the "CALIBRATION SUCCESSFUL" screen will be displayed.
![]() | |
Illustration 15 | g01203291 |
![]() | |
Illustration 16 | g01203292 |
- The "CALIBRATION UNSUCCESSFUL" screen and an error code will be displayed if the calibration is unsuccessful.
![]() | |
Illustration 17 | g01203295 |