VT-30, VT-40, VT-50 and VT-60 Multi-Processors Gerotor Motor Leakage - Test Caterpillar


Gerotor Motor Leakage - Test
`

------ WARNING! ------

At operating temperature, the hydraulic oil is hot and under pressure. Hot oils can cause burns.

To prevent possible personal injury, release the pressure in the work tool hydraulic circuit (boom, stick, bucket, and swing), travel circuits, and the hydraulic oil tank at the filler cap before any hydraulic lines or components are disconnected or removed.

Remove the filler cap only when the engine is stopped and the filler cap is cool enough to touch.

----------------------


NOTICE

Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the machine. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.

Dispose of all fluids according to local regulations.


Table 1
Required Tools    
Tool     Part Number     Part Description     Qty    
A     4C-4892     ORFS Fittings Group     1    
8T-0859 Pressure Gauge
 (1)

25000 kPa (3620 psi)    
1    
( 1 ) Part of 4C-4892 ORFS Fittings Group

  1. Inspect the rotate circuit for external leakage. If a leak is found, perform the necessary repairs. If there is no sign of leakage, proceed to the next step.

  1. Check each control valve for the proper operating pressure. Refer to Service Manual, "Control Valve Pressure (Hydraulic Rotator) - Test". The control valve must be operating at the proper pressure in order for this test to be valid.

  1. Adjust the pressure of the host machine for the rotate circuit to 12000 ± 500 kPa (1740 ± 70 psi). Refer to Service Manual for the host machine for the adjustment procedure.



    Illustration 1g01894255

    (CW) Rotate circuit clockwise and (CCW) Rotate circuit counterclockwise




    Illustration 2g01894315

  1. Remove hose assembly (1) from the work tool. Plug the hose from the machine. Cap the coupling on the work tool. This will prevent oil from returning to the hydraulic tank.

  1. Install Tooling (A) on test fitting (2) for the return side of the circuit.

  1. Start the engine of the host machine and operate the machine until the hydraulic oil reaches normal operating temperature.

  1. Open the jaws of the work tool. In order to prevent rotation, rotate the work tool to a horizontal position. Place the work tool on the ground. Place downward pressure on the work tool in order to prevent the work tool from rotating.

  1. Attempt to rotate the work tool in a counterclockwise direction. Record the reading on the pressure gauge.

  1. If the pressure on the pressure gauge increases, the gerotor motor must be repaired. Refer to Service Manual, "Gerotor Motor - Disassemble".

  1. The air must be purged from the work tool before the tool is returned to operation. Refer to Service Manual, "Hydraulic System Air - Purge" for the proper procedure.

Information System:

VT-30, VT-40, VT-50 and VT-60 Multi-Processors Hydraulic Cylinder Leakage - Test
VT-30, VT-40, VT-50 and VT-60 Multi-Processors Hydraulic Cylinder Leakage - Test
VT-30, VT-40, VT-50 and VT-60 Multi-Processors Control Valve Pressure (Hydraulic Rotator) - Test
VT-30, VT-40, VT-50 and VT-60 Multi-Processors Control Valve Pressure (Hydraulic Rotator) - Test
VT-30, VT-40, VT-50 and VT-60 Multi-Processors Hydraulic System Air - Purge
C9.3 Engines for Caterpillar Built Machines General Information
Hydraulic Quick Coupler Quick Coupler Operation - Hydraulic Pin Grabber Quick Coupler (If Equipped)
2010/08/23 The Harness Mounting of the Liquid Level Switch on the Engine Oil Pan is Improved on Certain 345D Excavators {1302}
345C UHD Excavator and 345C Mobile Hydraulic Power Unit Maintenance Interval Schedule
374D Excavator Hydraulic System Stick Drift Reduction Valve
374D Excavator Hydraulic System Stick Hydraulic System
374D Excavator Hydraulic System Boom Drift Reduction Valve
VT-30, VT-40, VT-50 and VT-60 Multi-Processors Gerotor Motor Leakage - Test
VT-30, VT-40, VT-50 and VT-60 Multi-Processors Swivel Leakage - Test
VT-30, VT-40, VT-50 and VT-60 Multi-Processors Swivel Leakage - Test
VT-30, VT-40, VT-50 and VT-60 Multi-Processors Host Machine Pressure and Flow - Test
568 Forest Machine Machine Electronic Control System Using the Operator Monitor to Determine Diagnostic Codes
390D Excavator Operator Controls
C9.3 Engines for Caterpillar Built Machines Alternator Problem - Charging Problem and/or Noisy Operation
C9.3 Engines for Caterpillar Built Machines Coolant Contains Oil
C9.3 Engines for Caterpillar Built Machines Coolant Contains Fuel
C9.3 Engines for Caterpillar Built Machines Coolant Temperature Is High
C9.3 Engines for Caterpillar Built Machines Coolant Temperature Is Low
303.5D CR, 304D CR, 305D CR and 305.5D CR Mini Hydraulic Excavators Specifications