M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0374 - FMI 06 Caterpillar


MID 039 - CID 0374 - FMI 06
`

Conditions Which Generate This Code:




Illustration 1g00840422

Schematic of the Solenoid valve (swing brake)

This diagnostic code is associated with the Solenoid valve (swing brake). The FMI 06 means that the machine ECM has determined that the current of the solenoid is above normal.

The possible causes of this diagnostic code are listed:

  • The energize circuit of the solenoid is shorted to ground.

  • The solenoid has failed.

  • The machine ECM has failed. This is unlikely.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0374 FMI 06 is active before performing this procedure.

Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.

System Response:

When this diagnostic code is active, the machine ECM will be unable to control the swing brake. The swing brake will always be activated.

Test Step 1. CHECK THE SOLENOID.

  1. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.

  1. Observe the status of the diagnostic code.

  1. Disconnect the solenoid with the active diagnostic code from the machine harness.

Expected Result:

CID 0374 FMI 06 changes to CID 0374 FMI 05 when the solenoid is disconnected.

Results:

  • YES - CID 0374 FMI 06 changes to CID 0374 FMI 05 when the solenoid is disconnected. The circuit is correct.

    Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid.

    Stop.

  • NO - CID 0374 FMI 06 remains active. Proceed to Test Step 2.

Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.

  1. Turn the key start switch and the disconnect switch to the OFF position.

  1. The solenoid remains disconnected from the machine harness.

  1. Disconnect the machine harness connector(s) from the machine ECM.

  1. At the machine harness connector, measure the resistance from the signal contact J2-51 (wire C995-YL) to all contacts that are used in the machine harness connectors for the machine ECM.

Expected Result:

Each resistance measurement is greater than 5000 ohms.

Results:

  • OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.

  • NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-51 (wire C995-YL) and the circuit with the low resistance measurement.

    Repair: Repair the machine harness or replace the machine harness.

    Stop.

Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.

  1. Inspect the harness connectors and clean the contacts of the harness connectors.

  1. Reconnect all harness connectors.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Operate the machine.

  1. Check the status of the CID 0374 FMI 06.

Expected Result:

The CID 0374 FMI 06 is active.

Results:

  • YES - The CID 0374 FMI 06 is active. The diagnostic code has not been corrected. The machine ECM may have failed.

    Repair: It is unlikely that the machine ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the machine ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    Stop.

  • NO - The CID 0374 FMI 06 is not active. The diagnostic code does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    Stop.

Information System:

M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0374 - FMI 05
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0374 - FMI 03
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0298 - FMI 05
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0298 - FMI 04
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0291 - FMI 06
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0291 - FMI 05
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0291 - FMI 03
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System Logged Events Menu
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System Introduction
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System Hydraulic Activation Control Function
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System Glossary of Terms
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System Generator Function
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0444 - FMI 03
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0444 - FMI 05
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0444 - FMI 06
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0598 - FMI 03
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0598 - FMI 05
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0598 - FMI 06
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0681 - FMI 03
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0681 - FMI 05
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0681 - FMI 06
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0736 - FMI 03
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0736 - FMI 06
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0882 - FMI 03