M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 1623 - FMI 03 Caterpillar


MID 039 - CID 1623 - FMI 03
`

Conditions Which Generate This Code:




Illustration 1g00865910

Schematic of the Brake Lights

This diagnostic code is associated with the Brake Lights. The FMI 03 means that the ECM has determined that the voltage of the lamp circuit is above normal.

The possible causes of the diagnostic code are listed:

  • The indicator lamp has failed.

  • The energize circuit of the indicator lamp is shorted to the +battery circuit.

  • The ECM has failed. This is unlikely.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1623 FMI 03 is active before performing this procedure.

Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.

Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE INDIAVSOR LAMP FOR A SHORT TO THE +BATTERY CIRCUIT.

  1. Turn the key start switch and the disconnect switch to the OFF position.

  1. Disconnect the machine harness connectors from the indicator lamp and the ECM.

  1. At the machine harness connector for the ECM, measure the resistance from contact J2-4 (wire A618-OR) and J2-16 (wire 604-OR) to all contacts that are used in the machine harness connectors for the ECM.

Expected Result:

Each resistance measurement is greater than 5000 ohms.

Results:

  • OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.

  • NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between the circuit that has a low resistance measurement and either the contact J2-4 (A618-OR) or the contact J2-16 (wire 604-OR).

    Repair: Repair the machine harness or replace the machine harness.

    Stop.

Test Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.

  1. Inspect the contacts and clean the contacts of the harness connectors.

  1. Reconnect all harness connectors.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Operate the machine.

  1. Determine if the CID 1623 FMI 03 is active.

Expected Result:

The CID 1623 FMI 03 is active.

Results:

  • YES - The CID 1623 FMI 03 is active. The problem has not been corrected. The ECM may have failed.

    Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    Stop.

  • NO - The CID 1623 FMI 03 is not active. The problem does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    Stop.

Information System:

M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 1622 - FMI 06
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 1622 - FMI 05
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 1622 - FMI 03
3126B Engine for Caterpillar Built Machines Engine Temperature Sensor Open or Short Circuit - Test
305 Mini Hydraulic Excavator Machine Systems Bucket Cylinder - Install
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0376 - FMI 06
311B, 312B, 315B, 318B, 320B, 322B, 325B, 330B, 345B, 345B Series II, 365B and 385B Excavators Air Conditioning and Heating General Information
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0376 - FMI 05
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 0376 - FMI 03
305 Mini Hydraulic Excavator Machine Systems Bucket Cylinder - Remove
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 1683 - FMI 03
37-MT, 41-MT, and 42-MT Series Starting Motors General Information
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 1623 - FMI 05
304 Mini Hydraulic ExcavatorEngine Supplement and Machine Systems Boom Cylinder - Remove
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 1623 - FMI 06
GH52,GH55,GH60 Hydraulic Excavator Forestry Grapples Swivel - Disassemble
322C Excavator Machine System Specifications Pilot Lines - Pump Flow Control
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 1683 - FMI 05
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 1683 - FMI 06
312C Excavator Machine Systems Main Control Valve - Disassemble
M313C, M315C, M316C, M318C, M318C MH, M322C and M322C MH Excavators Electronic System MID 039 - CID 1670 - FMI 04
GH52,GH55,GH60 Hydraulic Excavator Forestry Grapples Swivel - Assemble
304 CR and 305 CR Mini Hydraulic Excavators Electric and Electronic Systems Horn Does Not Sound - Troubleshoot
304 CR and 305 CR Mini Hydraulic Excavators and 313B CR and 321B LCR Excavators Air Conditioning and Heating General Information