Product Link - PL522/523 Diagnostics and Events Not Available Caterpillar


Diagnostics and Events Not Available
`

System Operation Description:

There are problems that could be reported with the PL522 or 523 system but the problems are not caused by the PL522 or 523 system. The problem is that the diagnostic information or events are not received at the office. This section contains steps that are used to determine the possible cause. Check for active diagnostic codes for the PL522 or 523. Correct any diagnostic codes before proceeding. Visually inspect the following items for damage: PL522 or 523 module, antenna and cables. Verify that there are no loose connections.

The PL522 and 523 system depends on several communication links in order to transfer data from the machine to the office. The following procedures assume that these communication links are operating properly. The proper communication links are listed below:

  • The network for cellular communications is operational in the geographic area of concern. The network is operational when messages can be sent to VisionLink.

  • The PL522 or 523 system is correctly configured to communicate on the network for cellular communications.

  • The worldwide network of AVSpares computers is passing messages to software of the AVSpare VisionLink.

  • The AVSpare Electronic Technician (Cat ET ) is configured properly and the software is functioning.

The PL522 or 523 modules should not be replaced without verifying that these issues have been investigated. Contact your AVSpare Technical Communicator for aid in resolving these issues.

The PL522 or 523 can be configured in order to transmit diagnostics and events to the office. These transmissions are highly dependent on the configuration of the PL522 or 523. The following troubleshooting steps assume that the position and the standard report are being received.

Test Step 1. ACCESS THE PL522 AND 523 THROUGH THE AVS ET SERVICE TOOL.

  1. Connect the Cat ET service tool to the machine.

  2. Verify that the ECM (VIMS Main Module) is present.

Expected Result:

The ECM (VIMS Main Module) is present.

Results:

  • OK - The ECM (VIMS Main Module) is present. Proceed to Test Step 2.

  • NOT OK - The ECM (VIMS Main Module) is not present in the Cat ET screen.

    Repair: Verify that the wiring for the PL522 or 523 has been installed correctly. Check the wiring with a multimeter. If the ECM ( VIMS Main Module) is not available, see Systems Operation, Troubleshooting, Testing and Adjusting, "Electronic Service Tool Does Not Communicate with ECM".

    STOP

Test Step 2. CHECK FOR LOGGED EVENTS OR DIAGNOSTICS THAT MAY HAVE OCCURRED.

Use the Cat ET service tool to verify the existence of logged events or diagnostics on other ECM systems. Note any events and diagnostics that are not reported.

Expected Result:

There are no logged events or diagnostics that should have been reported.

Results:

  • OK - There are no logged events or diagnostics that should have been reported. The PL522 or 523 appears to be working correctly.

    STOP

  • NOT OK - There are logged events or diagnostics that should have been reported. Monitor the operation of the PL522 or 523 for reporting of events and diagnostics. Problems in this area are not usually a problem with the device. The device should not be replaced.

    STOP

Information System:

Product Link - PL522/523 Reporting Interval Erratic
Product Link - PL522/523 Position Reports Not Available
Crimputer III Setup and Operation{0684, 5057}
312D2 and 313D2 Excavators Machine System Specifications Control Valve
312D and 313D Excavators Machine System Specifications Pump Lines (Auxiliary)
C4.4 Industrial Engine Engine Oil Pump - Inspect
312D and 313D Excavators Machine System Specifications Front Lines - System 22
374D Excavator Hydraulic System Specifications
Product Link - PL522/523 Reports and Messages Not Available
Rework Procedure for the Insulation Group Around the Cooling Arrangement for 307D Excavators{7150, 7251, 726A, 7276, 7301}
349E Excavator Hydraulic System Travel Hydraulic System
Product Link - PL522/523 Electronic Service Tool Does Not Communicate with ECM
Replacing Tubes In Housings That Are Installed With Mechanical Joints (Expanded and Welded) {3016, 3154, 4104, 4133, 5057}
Product Link - PL522/523 Operating Hours Discrepancy
Product Link - PL522/523 MID 161 - CID 0168 - FMI 00
320E and 323E Excavators Specifications
320E and 323E Excavators Boom/Stick/Bucket Combinations
374D Excavator Hydraulic System Relief Valve (Crossover) - Test and Adjust
Product Link - PL522/523 MID 161 - CID 0168 - FMI 01
Product Link - PL522/523 MID 161 - CID 0254 - FMI 04
374D Excavator Hydraulic System Relief Valve (Counterweight Cylinder) - Test and Adjust
Product Link - PL522/523 MID 161 - CID 1251 - FMI 03
A New Torque Value Is Used for the Fuel Pressure Regulator Valves on Certain Diesel Engines{1251, 1262, 1274}
323F SA and 323F LN Excavator Access Door and Cover Locations