Product Link - PL522/523 MID 161 - CID 1251 - FMI 03 Caterpillar


MID 161 - CID 1251 - FMI 03
`
MID 161 CID 1251 FMI 03

Conditions Which Generate This Code:

The PL522 or 523 modules track the machine operating hours for reporting to the office. The Alternator R-Terminal signal is used to detect when the machine is operating. If the input continually receives a voltage signal that is above normal, then machine operation cannot be detected. Also, the reported Service Meter Hours (SMU) would be inaccurate.

Test Step 1. CHECK THE R-TERMINAL CABLING FOR SHORT TO BATTERY.

  1. Disconnect the PL522 or 523 cable (P1) from the PL522 or 523 module.

  2. Measure the resistance from the Alternator R-terminal input J1-4 (403MC9-GN(Green) to battery (J1-1).

Expected Result:

The resistance should be greater than 5000 ohms.

Results:

  • OK - The PL522 or 523 harness is likely correct. Proceed to Test Step 2.

  • NOT OK - The PL522 or 523 cable has a probable short to battery.

    Repair: Repair the cable and verify that the fault has been removed.

    STOP

Test Step 2. CHECK THE PL522 AND 523 HARNESS FOR A SHORT TO A VOLTAGE SOURCE.

  1. Disconnect the PL522 or 523 cable (P1) from the PL522 or 523 module.

  2. Start the engine.

  3. Measure the Alternator R-Terminal input (J1-4) to verify that there is an 11 VDC to 32 VDC square-wave. The measurement should range from 5Hz to 2 kHz or a steady DC voltage equivalent to the battery present.

Expected Result:

The Alternator R-Terminal input does not measure at a steady DC voltage equivalent to the battery voltage.

Results:

  • OK - The signal is an 11 VDC to 32 VDC square-wave. The measurement should range from 0kHz to 2 kHz or a steady DC voltage equivalent to the battery present. The PL522 or 523 harness is likely not faulty. Proceed to Test Step 3.

  • NOT OK - The PL522 or 523 cable has a possible short to a DC voltage source other than battery voltage.

    Repair: Repair the cable and verify that the fault has been removed.

    STOP

Test Step 3. CHECK THE MACHINE ALTERNATOR.

  1. Disconnect the PL522 or 523 machine cable from the alternator.

  2. Start the engine.

  3. Using a multimeter and scope, measure the Alternator R-Terminal to verify that there is 11 VDC to 32 VDC square-wave. The measurement should range from 0 kHz to 2 kHz.

Expected Result:

The alternator R-Terminal should be an 11 VDC to 32 VDC square-wave from 0 kHz to 2 kHz.

Results:

  • OK - The alternator R-Terminal is an 11 VDC to 32 VDC square-wave from 0 kHz to 2 kHz. Proceed to Test Step 4.

  • NOT OK - The alternator R-Terminal is not an 11 VDC to 32 VDC square-wave from 0 kHz to 2 kHz.

    Repair: Repair the alternator or replace the alternator.

    STOP

Test Step 4. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.

  1. Clean the contacts of the harness connectors.

  2. Reconnect all harness connectors.

  3. Turn the key start switch to the ON position and operate the machine.

  4. Determine if "CID 1251 FMI 03" diagnostic code is present by using the AVSpare Electronic Technician (Cat ET ).

Expected Result:

A "CID 1251 FMI 03" diagnostic code is present.

Results:

  • YES - The problem has not been corrected. ECM failure is unlikely.

    Repair: Perform this diagnostic test procedure again. If the cause of the diagnostic code is not found, replace the Product Link ECM. Before replacing the PL522 or 523, contact your AVSpare Technical Communicator. Refer to Systems Operation, Troubleshooting, Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

  • NO - The diagnostic code is NOT present. The problem does not exist at this time. The initial problem was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Information System:

374D Excavator Hydraulic System Relief Valve (Counterweight Cylinder) - Test and Adjust
Product Link - PL522/523 MID 161 - CID 0254 - FMI 04
Product Link - PL522/523 MID 161 - CID 0168 - FMI 01
374D Excavator Hydraulic System Relief Valve (Crossover) - Test and Adjust
320E and 323E Excavators Boom/Stick/Bucket Combinations
320E and 323E Excavators Specifications
Product Link - PL522/523 MID 161 - CID 0168 - FMI 00
Product Link - PL522/523 Operating Hours Discrepancy
Replacing Tubes In Housings That Are Installed With Mechanical Joints (Expanded and Welded) {3016, 3154, 4104, 4133, 5057}
Product Link - PL522/523 Diagnostics and Events Not Available
Product Link - PL522/523 Reporting Interval Erratic
Product Link - PL522/523 Position Reports Not Available
A New Torque Value Is Used for the Fuel Pressure Regulator Valves on Certain Diesel Engines{1251, 1262, 1274}
323F SA and 323F LN Excavator Access Door and Cover Locations
320E and 323E Excavators Engine Starting with Auxiliary Start Receptacle - If Equipped
312D and 313D Excavators Machine System Specifications Front Lines - Quick Coupler
Product Link - PL522/523 Electronic Control Module (ECM) - Flash Program
Product Link - PL522/523 Electrical Connector - Inspect
Product Link - PL522/523 System Schematic
374D Excavator Hydraulic System Main Pump (Flow) - Test - Constant Horsepower Flow Control
374D Excavator Hydraulic System Travel on Level Ground - Test - Optional Test
349E Excavator Hydraulic System Stick Drift Reduction Valve
374D Excavator Hydraulic System Main Pump (Destroke Pressure) - Test and Adjust
Installation Procedure for Product Link PL522 and PL523 (Cellular) {7606}