C6.6 Industrial Engine Coolant Temperature Sensor - Remove and Install Caterpillar


Coolant Temperature Sensor - Remove and Install
`
1.1. Removal Procedure
2.1. Installation Procedure

Removal Procedure


NOTICE

Keep all parts clean from contaminants.

Contaminants may cause rapid wear and shortened component life.



NOTICE

Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.

Dispose of all fluids according to local regulations and mandates.


  1. Drain the coolant from the cooling system to a level below the coolant temperature sensor. Refer to Operation and Maintenance Manual, "Cooling System Coolant - Change" for the correct draining procedure.


    Illustration 1g02025016

  2. Slide locking tab (2) into the unlocked position. Disconnect harness assembly (1) from coolant temperature sensor (3).

  3. Use a deep socket in order to remove coolant temperature sensor (3) from the cylinder head.

  4. Remove O-ring seal (4) from coolant temperature sensor (3).

Installation Procedure


NOTICE

Keep all parts clean from contaminants.

Contaminants may cause rapid wear and shortened component life.




    Illustration 2g02025016

  1. Install a new O-ring seal (4) onto coolant temperature sensor (3).

    Note: Do not lubricate the O-ring seal.

  2. Use a deep socket in order to install coolant temperature sensor (3) to the cylinder head. Tighten the coolant temperature sensor to a torque of 20 N·m (177 lb in).

  3. Connect harness assembly (1) to coolant temperature sensor (3). Slide locking tab (2) into the locked position.

  4. Fill the cooling system to the correct level. Refer to Operation and Maintenance Manual, "Cooling System Coolant Level - Check" and refer to Operation and Maintenance Manual, "Cooling System Coolant - Change" for the correct filling procedures.

Information System:

C6.6 Industrial Engine Crankshaft Position Sensor - Remove and Install
C6.6 Industrial Engine Camshaft Position Sensor - Remove and Install
345C MHPU Mobile Hydraulic Power Unit Hydraulic System Joystick Control - Calibrate
336D MHPU Mobile Hydraulic Power Unit Hydraulic System Combined Function Hydraulic System - System 18
345C MHPU Mobile Hydraulic Power Unit Hydraulic System System Pressure - Release
C4.4 Industrial Engine Alternator
336E Excavator and 336E MHPU Mobile Hydraulic Power Unit Machine Systems Boom Bearings and Seals - Remove and Install
336E Excavator and 336E MHPU Mobile Hydraulic Power Unit Machine Systems Boom - Remove and Install
336E Excavator and 336E MHPU Mobile Hydraulic Power Unit Machine Systems Boom Cylinder - Remove and Install
C9.3 Engines for Caterpillar Built Machines Rocker Arm and Shaft - Remove
C6.6 Industrial Engine Atmospheric Pressure Sensor - Remove and Install
C6.6 Industrial Engine Refrigerant Compressor - Remove and Install
C6.6 Industrial Engine Engine Oil Pressure Sensor - Remove and Install
C6.6 Industrial Engine Soot Antenna - Remove and Install
C6.6 Industrial Engine Temperature Sensor (DPF) - Remove and Install
C6.6 Industrial Engine Temperature Sensor (Cooled Exhaust Gas) - Remove and Install
C6.6 Industrial Engine Pressure Sensor (Cooled Exhaust Gas) - Remove and Install - NRS Inlet and Outlet Pressure Sensors
C6.6 Industrial Engine Boost Pressure Sensor - Remove and Install
C6.6 Industrial Engine Inlet Manifold Temperature Sensor - Remove and Install
C6.6 Industrial Engine Glow Plugs - Remove and Install
C6.6 Industrial Engine Alternator Belt - Remove and Install
C6.6 Industrial Engine Idler Pulley - Remove and Install - Grooved Idler Pulley
C6.6 Industrial Engine Idler Pulley - Remove and Install - Flat Idler Pulley
C6.6 Industrial Engine Belt Tensioner - Remove and Install