C6.6 Industrial Engine Boost Pressure Sensor - Remove and Install Caterpillar


Boost Pressure Sensor - Remove and Install
`
1.1. Removal Procedure
2.1. Installation Procedure

Removal Procedure


NOTICE

Keep all parts clean from contaminants.

Contaminants may cause rapid wear and shortened component life.




    Illustration 1g02022982

  1. Slide locking tab (1) into the unlocked position.

  2. Disconnect harness assembly (2) from boost pressure sensor (3).

    Note: The boost pressure sensor has a three-wire plug.

  3. Use a deep socket to remove boost pressure sensor (3) from the inlet manifold.

  4. Remove O-ring seal (4) from the boost pressure sensor (3).

Installation Procedure


NOTICE

Keep all parts clean from contaminants.

Contaminants may cause rapid wear and shortened component life.




    Illustration 2g02022982

  1. Install a new O-ring seal (4) onto boost pressure sensor (3).

    Note: Do not lubricate the O-ring seal.

  2. Use a deep socket to install boost pressure sensor (3) to the inlet manifold. Tighten the boost pressure sensor to a torque of 10 N·m (89 lb in).

  3. Connect harness assembly (2) to boost pressure sensor (3).

  4. Slide locking tab (1) into the locked position.

Information System:

C6.6 Industrial Engine Pressure Sensor (Cooled Exhaust Gas) - Remove and Install - NRS Inlet and Outlet Pressure Sensors
C6.6 Industrial Engine Temperature Sensor (Cooled Exhaust Gas) - Remove and Install
C6.6 Industrial Engine Temperature Sensor (DPF) - Remove and Install
C6.6 Industrial Engine Soot Antenna - Remove and Install
C6.6 Industrial Engine Engine Oil Pressure Sensor - Remove and Install
C6.6 Industrial Engine Coolant Temperature Sensor - Remove and Install
C6.6 Industrial Engine Crankshaft Position Sensor - Remove and Install
C6.6 Industrial Engine Camshaft Position Sensor - Remove and Install
345C MHPU Mobile Hydraulic Power Unit Hydraulic System Joystick Control - Calibrate
336D MHPU Mobile Hydraulic Power Unit Hydraulic System Combined Function Hydraulic System - System 18
345C MHPU Mobile Hydraulic Power Unit Hydraulic System System Pressure - Release
C4.4 Industrial Engine Alternator
C6.6 Industrial Engine Inlet Manifold Temperature Sensor - Remove and Install
C6.6 Industrial Engine Glow Plugs - Remove and Install
C6.6 Industrial Engine Alternator Belt - Remove and Install
C6.6 Industrial Engine Idler Pulley - Remove and Install - Grooved Idler Pulley
C6.6 Industrial Engine Idler Pulley - Remove and Install - Flat Idler Pulley
C6.6 Industrial Engine Belt Tensioner - Remove and Install
C6.6 Industrial Engine Fan - Remove and Install
C6.6 Industrial Engine Fan Drive - Remove and Install
C6.6 Industrial Engine Electronic Control Module - Remove and Install - Electronic Control Module With Banjo Bolt Connections
C6.6 Industrial Engine Electronic Control Module - Remove and Install - Electronic Control Module With Quick Coupler Connections
C6.6 Industrial Engine ECM Mounting Bracket - Remove and Install
C6.6 Industrial Engine Alternator - Remove