C6.6 Industrial Engine Fan - Remove and Install Caterpillar


Fan - Remove and Install
`
1.1. Removal Procedure
2.1. Installation Procedure

Removal Procedure

Start By:

  1. Remove the alternator belt. Refer to Disassembly and Assembly, "Alternator Belt - Remove and Install" for the correct procedure.


    Illustration 1g02320097
    Typical example

  1. Remove locking nuts (1).

  2. Remove fan (2).

    Note: Note the orientation of the fan.

  3. Remove fan adapter (3).

  4. Remove fan pulley (4).

  5. If necessary, remove studs (5) from fan drive (6).

Installation Procedure

  1. Ensure that all the components are free from wear and damage. If necessary, replace any components that are worn or damaged.


    Illustration 2g02320097
    Typical example

  2. If necessary, install studs (5) to fan drive (6). Tighten studs (5) to a torque of 11 N·m (97 lb in).

  3. If studs (5) have not been previously removed from fan drive (6). Check for the correct installation of the studs to the fan drive. Tighten studs (5) to a torque of 11 N·m (97 lb in).

  4. Install fan pulley (4).

  5. Install fan adapter (3).

  6. Install fan (2).

    Note: Ensure that the fan is correctly oriented.

  7. Inspect the condition of locking nuts (1). If necessary, replace the locking nuts. Install locking nuts (1). Tighten locking nuts (1) to a torque of 22 N·m (195 lb in).

End By:

  1. Install the Alternator Belt. Refer to Disassembly and Assembly, "Alternator Belt - Remove and Install" for the correct procedure.

Information System:

C6.6 Industrial Engine Belt Tensioner - Remove and Install
C6.6 Industrial Engine Idler Pulley - Remove and Install - Flat Idler Pulley
C6.6 Industrial Engine Idler Pulley - Remove and Install - Grooved Idler Pulley
C6.6 Industrial Engine Alternator Belt - Remove and Install
C6.6 Industrial Engine Glow Plugs - Remove and Install
C6.6 Industrial Engine Inlet Manifold Temperature Sensor - Remove and Install
C6.6 Industrial Engine Boost Pressure Sensor - Remove and Install
C6.6 Industrial Engine Pressure Sensor (Cooled Exhaust Gas) - Remove and Install - NRS Inlet and Outlet Pressure Sensors
C6.6 Industrial Engine Temperature Sensor (Cooled Exhaust Gas) - Remove and Install
C6.6 Industrial Engine Temperature Sensor (DPF) - Remove and Install
C6.6 Industrial Engine Soot Antenna - Remove and Install
C6.6 Industrial Engine Engine Oil Pressure Sensor - Remove and Install
C6.6 Industrial Engine Fan Drive - Remove and Install
C6.6 Industrial Engine Electronic Control Module - Remove and Install - Electronic Control Module With Banjo Bolt Connections
C6.6 Industrial Engine Electronic Control Module - Remove and Install - Electronic Control Module With Quick Coupler Connections
C6.6 Industrial Engine ECM Mounting Bracket - Remove and Install
C6.6 Industrial Engine Alternator - Remove
C6.6 Industrial Engine Electric Starting Motor - Remove and Install
C6.6 Industrial Engine Alternator - Install
C6.6 Industrial Engine Air Compressor - Remove and Install - Twin Cylinder Compressor
C6.6 Industrial Engine Air Compressor - Remove and Install - Single Cylinder
324E Excavator Safety Messages
C4.4 Industrial Engine Air Inlet and Exhaust System - Single Turbocharger
324E Excavator Additional Messages